Parameter |
Short Description |
Long Description |
|
Capacity |
Heating capacity value of pipe segments and equipment |
For connected Equipment: Set heating capacity in Equipment Settings, MEP Calculation Input Data |
|
Mass flow |
Mass flow value for pipe segments and equipment |
Calculated automatically based on element capacities and supply/return temperatures. Visible in MEP System Browser. |
|
Temperature Return |
Return temperature for pipe segments and equipment |
For pipe segment: Set return temp in Hydronic System Settings Override this value in connected Equipment: Use Equipment Settings, MEP Calculation Input Data |
|
Temperature Supply |
Supply temperature for pipe segments and equipment |
For pipe segment and connected Equipment: Set supply temp in Hydronic System Settings |
|
Combined Temperatures |
Display both supply and return temperature values |
Display data in labels and schedules |
|
Velocity |
Velocity value for pipe segments and equipment |
Calculated automatically based on element capacities and supply/return temperatures. Visible in MEP System Browser. |