MEP elements in IFC exchange

Available with Archicad Collaborate

At IFC import

MEP elements are converted as shown in this table.

Incoming element

Converted to Archicad as

segment

fitting

takeoff

fitting

segment + takeoff

equipment

port 1

terminal

port 2

accessory or fitting (depending on location of port)

port 3 and all other ports

fitting

At IFC export

See the MEP tools section at Built-in IFC Type Mapping.