Zoning Clearance
Use Zoning ClearanceZoning Clearance to check whether Buildings remain within the 3D Constraints defined for a Site. The check finds collisions between the allowable 3D volume and both the Building geometry and the Units placed on the Building.
Zoning Clearance also checks whether placed Units overlap each other. Overlapping Units can cause the same floor area to be counted twice, which makes area metrics inaccurate.
Run Zoning Clearance after changing a Building’s height, position, footprint, Floors, or below-ground elements.
Before you begin
Make sure that the Site contains at least one 3D Constraint and that it has been configured to represent the applicable setbacks, height limits, and other zoning boundaries.
Run the check
- Open
Compliance CheckCompliance Checkfrom the Data and Analytics bar. - Select
Run zoning clearance checkRun zoning clearance check. - Review the results in the
Zoning ClearanceZoning Clearanceinterface. - If a warning appears, adjust the affected Building or or 3D Constraint.
- Run the check again after making changes.
A warning appears when a Building extends beyond a 3D Constraint. This can include a small corner that projects through a slanted Constraint surface or a below-ground portion, such as parking, that extends beyond the permitted volume.

How multiple Constraints work
Zoning Clearance evaluates the combined volume of connected 3D Constraints.
For example, you can define adjacent Constraints with different height limits. If the Constraints meet without gaps or overlaps, Creator treats them as one continuous buildable envelope. A Building located on the shared boundary does not generate a warning solely because it crosses from one connected Constraint into another.
Resolve a warning
When Zoning Clearance identifies a conflict:
Next steps
- Create 3D Constraints — Add, edit, or remove the Constraints used by the check.
- Create a Building — Modify the Building that generated the warning.
- Run a Compliance Check — Review measurable Site targets, such as coverage, Floor Area Ratio, and total floor area.
- Design Options — Compare alternative Building designs against the same Site rules.